Sphere-9™ catheter

Official notice

27 Jul 2026

Last checked

13 Nov 2026

RecallScope risk estimate:HighHealth Canada

An official Health Canada notice concerns Sphere-9™ catheter. There have been forty-six (46) reported incident reports (none of which were from Canada) where patients with a Biotronik ICD experienced induced ventricular arrhythmia (VT and/or VF) following RF ablation of cardiac tissue using the Affera Sphere-9 catheter. Sphere-9 presents a higher current flow to the ICD or CRT-D which interacts with a safety feature built into Biotronik ICDs and CRT-Ds. The higher currents of the Sphere-9 catheter during RF application proceed to an unfavorable modulation of the coupled currents (approx. 40Hz frequency) that may be conducted via the implanted leads, and result in possible VT or VF induction. Published 2026-07-27.

What to do now

Contact the manufacturer if you require additional information.

Recall number

82409

Official notice

2026-07-27

The hazard

There have been forty-six (46) reported incident reports (none of which were from Canada) where patients with a Biotronik ICD experienced induced ventricular arrhythmia (VT and/or VF) following RF ablation of cardiac tissue using the Affera Sphere-9 catheter. Sphere-9 presents a higher current flow to the ICD or CRT-D which interacts with a safety feature built into Biotronik ICDs and CRT-Ds. The higher currents of the Sphere-9 catheter during RF application proceed to an unfavorable modulation of the coupled currents (approx. 40Hz frequency) that may be conducted via the implanted leads, and result in possible VT or VF induction.

How to check if you’re affected

Compare the product name and identifiers below with the item you own. Check the official notice for the affected products and next steps.

Skus

AFR-00001

Other

RA RA-82409

Model numbers

AFR-00001

Recall Numbers

82409

Checked manually this time?

Follow brands and keywords in the app to receive alerts for matching official notices.

Turn on recall alerts

Affected products

Product 1

Lot or serial number - All lots., Model or catalogue number - AFR-00001

Hazard

There have been forty-six (46) reported incident reports (none of which were from Canada) where patients with a Biotronik ICD experienced induced ventricular arrhythmia (VT and/or VF) following RF ablation of cardiac tissue using the Affera Sphere-9 catheter. Sphere-9 presents a higher current flow to the ICD or CRT-D which interacts with a safety feature built into Biotronik ICDs and CRT-Ds. The higher currents of the Sphere-9 catheter during RF application proceed to an unfavorable modulation of the coupled currents (approx. 40Hz frequency) that may be conducted via the implanted leads, and result in possible VT or VF induction.

Where it was sold

Retailer information is not currently available in RecallScope. Check the official notice for distribution details.

Location 1

CA · Canada

Affected area 1

CA · Canada

Company & contacts

Manufacturer

Not provided

Phone

Not provided

Brand: Medtronic.

Source & status

Tier

beta

Category

Health

Official classification

Type I

Recall details

Recall number

82409

Source tier

beta

Documents, notices & source

See the official notice and source documents for full details.

View full official notice
Something wrong on this page?

Weekly recall digest

Get next week’s recalls before you need them.

One email every Monday with official-source recalls for your country, and nothing else. Unsubscribe from any email.

The digest arrives once a week. For matching recall alerts after notices are processed, get the app.

This recall was published 27 Jul 2026. The next one won’t wait for you to search.

RecallScope checks listed publishers for the brands and VINs you follow, and can alert you when a matching notice is processed.

apple-buttongoogle-button