Image not available in RecallScope.
Storage furniture (children's furniture) – (Product name) Magazine rack
Official notice
12 Dec 2023
Last checked
29 Oct 2026
An official Safety Korea notice concerns Storage furniture (children's furniture) – (Product name) Magazine rack. ㅇ Total lead exceeds the limit by a factor of 1.7 - Part: Polymer - plastic edge trim (BR) - Measured value: 174 mg/kg - Limit: 100 mg/kg or less ㅇ Total cadmium exceeds the limit by a factor of 9.4 - Part: Polymer - plastic edge trim (BR) - Measured value: 710 mg/kg - Limit: 75 mg/kg or less ㅇ Phthalate plasticizers exceed the limit by a factor of 19.1 - Part: Polymer - plastic edge trim (BR) - Measured values: DEHP 1.58 % DINP 0.33 % - Limit: Combined total of 0.1 % or less ㅇ Incomplete labeling - Surface treatment, year and month of manufacture, and intended age omitted Published 2023-12-12.
What to do now
ㅇ Consumers who have this product must stop using it immediately ㅇ Contact or visit the designated contact point to obtain a repair, replacement, refund, or other remedy
Official notice
2023-12-12
The hazard
The hazard
ㅇ Total lead exceeds the limit by a factor of 1.7 - Part: Polymer - plastic edge trim (BR) - Measured value: 174 mg/kg - Limit: 100 mg/kg or less ㅇ Total cadmium exceeds the limit by a factor of 9.4 - Part: Polymer - plastic edge trim (BR) - Measured value: 710 mg/kg - Limit: 75 mg/kg or less ㅇ Phthalate plasticizers exceed the limit by a factor of 19.1 - Part: Polymer - plastic edge trim (BR) - Measured values: DEHP 1.58 % DINP 0.33 % - Limit: Combined total of 0.1 % or less ㅇ Incomplete labeling - Surface treatment, year and month of manufacture, and intended age omitted
How to check if you're affected
How to check if you're affected
Compare the product name and identifiers below with the item you own. Check the official notice for the affected products and next steps.
Models
Checked manually this time?
Follow brands and keywords in the app to receive alerts for matching official notices.
Turn on recall alertsAffected products
Affected products
Product 1
Hazard
Where it was sold
Where it was sold
Retailer information is not currently available in RecallScope. Check the official notice for distribution details.
Location 1
Affected area 1
Company & contacts
Company & contacts
Manufacturer
Phone
Contact: 카멜드 코리아. Phone 070-7954-3838.
Source & status
Source & status
Recall details
Recall details
Status
Source tier
Documents, notices & source
See the official notice and source documents for full details.