Image available on the official notice.
Battery (Only Rechargeable Batteries)
Official notice
11 Dec 2025
Last checked
10 Nov 2026
An official Safety Korea notice concerns Battery (Only Rechargeable Batteries). ᄋ External short circuit and overcharge test failed 1. External short circuit test: Battery ignition (PCB) ※ Discharge conditions: 0.2C(1,000 mA), 3.0 V ※ Charge conditions: 0.2C(1,000 mA), 4.2 V, 0.05 C cut-off(100 mA) ※ External short circuit test start conditions: 22.7 °C, 82.62 mΩ, Battery OCV 4.104 V ※ Maximum temperature rise of the battery: 23.9 °C 2. Overcharge test: Battery ignition (PCB) ※ Discharge conditions: 0.2C(1,000 mA), 3.0 V ※ Overcharge test conditions: 6.0 V, 10.0 A (2.0 * 5,000 mA) Battery OCV 3.466 V ※ Maximum temperature rise of the battery: 32.9 °C ᄋ Risk of inflammation or explosion due to overheating when an overcurrent flows ᄋ Risk of inflammation and explosion exists Published 2025-12-29.
What to do now
ᄋ Consumers possessing this product should stop using it immediately. ᄋ Contact or visit the inquiry contact to receive repair, exchange, or refund.
Official notice
2025-12-29
The hazard
The hazard
ᄋ External short circuit and overcharge test failed 1. External short circuit test: Battery ignition (PCB) ※ Discharge conditions: 0.2C(1,000 mA), 3.0 V ※ Charge conditions: 0.2C(1,000 mA), 4.2 V, 0.05 C cut-off(100 mA) ※ External short circuit test start conditions: 22.7 °C, 82.62 mΩ, Battery OCV 4.104 V ※ Maximum temperature rise of the battery: 23.9 °C 2. Overcharge test: Battery ignition (PCB) ※ Discharge conditions: 0.2C(1,000 mA), 3.0 V ※ Overcharge test conditions: 6.0 V, 10.0 A (2.0 * 5,000 mA) Battery OCV 3.466 V ※ Maximum temperature rise of the battery: 32.9 °C ᄋ Risk of inflammation or explosion due to overheating when an overcurrent flows ᄋ Risk of inflammation and explosion exists
How to check if you're affected
How to check if you're affected
Compare the product name and identifiers below with the item you own. Check the official notice for the affected products and next steps.
Models
Checked manually this time?
Follow brands and keywords in the app to receive alerts for matching official notices.
Turn on recall alertsAffected products
Affected products
Product 1
Hazard
Where it was sold
Where it was sold
Retailer information is not currently available in RecallScope. Check the official notice for distribution details.
Location 1
Affected area 1
Company & contacts
Company & contacts
Brand
Manufacturer
Phone
Brand: 크레앙.
Source & status
Source & status
Recall details
Recall details
Status
Source tier
Documents, notices & source
See the official notice and source documents for full details.