Open official notice

Furniture (limited to household chests of drawers and office filing cabinets with a height of 762 mm or greater)(Furniture (limited to household chests of drawers and office filing cabinets with a height of 762 mm or greater))

Official notice

21 Sept 2023

Last checked

10 Nov 2026

RecallScope risk estimate:Not specifiedSafety Korea

An official Safety Korea notice concerns Furniture (limited to household chests of drawers and office filing cabinets with a height of 762 mm or greater)(Furniture (limited to household chests of drawers and office filing cabinets with a height of 762 mm or greater)). ᄋ The content of formaldehyde exceeding the allowable level by 1 3.4, 2 3.7 times. - Measured area: 1 Back board + Bottom board of the drawer, 2Side board. - measure value: 1 5.1 mg/L, 2 5.6 mg/L (Allowable level: an average of 1.5 mg/L or below). ᄋ Inadequate stability (uniform load) (Measured area: Finished product). - Result: Toppled. - Standard: When uniform load was applied to inside of all drawers, it shall not topple or fall. ᄋ Inadequate stability (wall-mounting fittings) (Measured area: Finished product). - Result: Wall mounting fittings not attached or not provided. - Standard: It either shall provide the wall mounting fittings or the furniture with the wall mounting fittings attached. ᄋ Insufficient labelling. - Product, structural member, surface treatment, manufacturer, caution in use missing. ᄋ Risk of visual impairment, skin breakdown, digestive and respiratory disorder if exposed to formaldehyde. ᄋ Risk of pinching a part of the body if it falls and inclines towards the front where a user stands. ᄋ Risk of providing wrong information. Published 2023-09-21.

What to do now

Consumer instructions are not currently available in RecallScope. Check the official notice for what to do.

Official notice

2023-09-21

The hazard

ᄋ The content of formaldehyde exceeding the allowable level by 1 3.4, 2 3.7 times. - Measured area: 1 Back board + Bottom board of the drawer, 2Side board. - measure value: 1 5.1 mg/L, 2 5.6 mg/L (Allowable level: an average of 1.5 mg/L or below). ᄋ Inadequate stability (uniform load) (Measured area: Finished product). - Result: Toppled. - Standard: When uniform load was applied to inside of all drawers, it shall not topple or fall. ᄋ Inadequate stability (wall-mounting fittings) (Measured area: Finished product). - Result: Wall mounting fittings not attached or not provided. - Standard: It either shall provide the wall mounting fittings or the furniture with the wall mounting fittings attached. ᄋ Insufficient labelling. - Product, structural member, surface treatment, manufacturer, caution in use missing. ᄋ Risk of visual impairment, skin breakdown, digestive and respiratory disorder if exposed to formaldehyde. ᄋ Risk of pinching a part of the body if it falls and inclines towards the front where a user stands. ᄋ Risk of providing wrong information.

How to check if you're affected

Compare the product name and identifiers below with the item you own. Check the official notice for the affected products and next steps.

Models

WINNERS 5-DRAWER CHEST

Checked manually this time?

Follow brands and keywords in the app to receive alerts for matching official notices.

Turn on recall alerts

Affected products

Product 1

가구(높이 762mm이상의 가정용 서랍장 및 사무용 파일링 캐비닛에 한정)(가구(높이 762mm이상의 가정용 서랍장 및 사무용 파일링 캐비닛에 한정))

Hazard

ᄋ The content of formaldehyde exceeding the allowable level by 1 3.4, 2 3.7 times. - Measured area: 1 Back board + Bottom board of the drawer, 2Side board. - measure value: 1 5.1 mg/L, 2 5.6 mg/L (Allowable level: an average of 1.5 mg/L or below). ᄋ Inadequate stability (uniform load) (Measured area: Finished product). - Result: Toppled. - Standard: When uniform load was applied to inside of all drawers, it shall not topple or fall. ᄋ Inadequate stability (wall-mounting fittings) (Measured area: Finished product). - Result: Wall mounting fittings not attached or not provided. - Standard: It either shall provide the wall mounting fittings or the furniture with the wall mounting fittings attached. ᄋ Insufficient labelling. - Product, structural member, surface treatment, manufacturer, caution in use missing. ᄋ Risk of visual impairment, skin breakdown, digestive and respiratory disorder if exposed to formaldehyde. ᄋ Risk of pinching a part of the body if it falls and inclines towards the front where a user stands. ᄋ Risk of providing wrong information.

Where it was sold

Retailer information is not currently available in RecallScope. Check the official notice for distribution details.

Location 1

KR · South Korea

Affected area 1

KR · South Korea

Company & contacts

Brand

인까사

Manufacturer

인까사

Phone

Not provided

Brand: 인까사.

Source & status

Tier

official

Category

HOME

Recall details

Status

published

Source tier

official

Documents, notices & source

See the official notice and source documents for full details.

View full official notice
Something wrong on this page?

Weekly recall digest

Get next week's recalls before you need them.

One email every Monday — official-source recalls for your country, and nothing else. Unsubscribe from any email.

The digest arrives once a week. For matching recall alerts after notices are processed, get the app.

This recall was published 21 Sept 2023. The next one won't wait for you to search.

RecallScope checks listed publishers for the brands and VINs you follow, and can alert you when a matching notice is processed.

apple-buttongoogle-button