Image not available in RecallScope.
Flexible vinyl chloride hose (polyvinyl chloride pipe) – Flexible vinyl chloride hose [household hose (7~13)]
Official notice
12 Dec 2023
Last checked
29 Oct 2026
An official Safety Korea notice concerns Flexible vinyl chloride hose (polyvinyl chloride pipe) – Flexible vinyl chloride hose [household hose (7~13)]. ㅇ Phthalate plasticizers exceed the limit by factors of ① 52.2 and ② 37.8 - Parts: ① PVC (outer layer) ② PVC (inner layer) - Measured values: ① Combined total 52 157 mg/kg ② Combined total 37 801 mg/kg - Limit: Combined total of 1000 mg/kg or less ㅇ Total lead exceeds the limit by a factor of 10.3 - Part: PVC (inner layer) - Measured value: 1 027 mg/kg - Limit: 100 mg/kg or less ㅇ Incomplete labeling - Length and year and month of manufacture omitted Published 2023-12-12.
What to do now
ㅇ Consumers who have this product must stop using it immediately ㅇ Contact or visit the designated contact point to obtain a repair, replacement, refund, or other remedy
Official notice
2023-12-12
The hazard
The hazard
ㅇ Phthalate plasticizers exceed the limit by factors of ① 52.2 and ② 37.8 - Parts: ① PVC (outer layer) ② PVC (inner layer) - Measured values: ① Combined total 52 157 mg/kg ② Combined total 37 801 mg/kg - Limit: Combined total of 1000 mg/kg or less ㅇ Total lead exceeds the limit by a factor of 10.3 - Part: PVC (inner layer) - Measured value: 1 027 mg/kg - Limit: 100 mg/kg or less ㅇ Incomplete labeling - Length and year and month of manufacture omitted
How to check if you're affected
How to check if you're affected
Compare the product name and identifiers below with the item you own. Check the official notice for the affected products and next steps.
Upcs
Models
Checked manually this time?
Follow brands and keywords in the app to receive alerts for matching official notices.
Turn on recall alertsAffected products
Affected products
Product 1
Hazard
Where it was sold
Where it was sold
Retailer information is not currently available in RecallScope. Check the official notice for distribution details.
Location 1
Affected area 1
Company & contacts
Company & contacts
Brand
Manufacturer
Phone
Brand: 아폴로. Contact: (주)아폴로산업. Phone 1688-0131.
Source & status
Source & status
Recall details
Recall details
Status
Source tier
Documents, notices & source
See the official notice and source documents for full details.
View full official noticeWeekly recall digest
Get next week's recalls before you need them.
One email every Monday — official-source recalls for your country, and nothing else. Unsubscribe from any email.
The digest arrives once a week. For matching recall alerts after notices are processed, get the app.