Image available on the official notice.
ヤマトプロテック(株) "Residential fire alarm: Kemu-P (YSA-510)" (sold from 2009–2010) - Replacement
Official notice
28 Jul 2010
Last checked
28 Oct 2026
An official CAA Japan notice concerns ヤマトプロテック(株) "Residential fire alarm: Kemu-P (YSA-510)" (sold from 2009–2010) - Replacement. Defective components may cause false alarms or false fault alerts to sound. Published 2010-07-28.
What to do now
Exchange for a replacement product.
Official notice
2010-07-28
The hazard
The hazard
Defective components may cause false alarms or false fault alerts to sound.
How to check if you're affected
How to check if you're affected
Compare the product name and identifiers below with the item you own. Check the official notice for the affected products and next steps.
Models
Checked manually this time?
Follow brands and keywords in the app to receive alerts for matching official notices.
Turn on recall alertsAffected products
Affected products
Product 1
Hazard
Where it was sold
Where it was sold
Retailer information is not currently available in RecallScope. Check the official notice for distribution details.
Location 1
Affected area 1
Company & contacts
Company & contacts
Brand
Manufacturer
Phone
Brand: ヤマトプロテック. Contact: ヤマトプロテック株式会社. Phone 0120-801-084.
Source & status
Source & status
Recall details
Recall details
Event id
Source tier
Documents, notices & source
See the official notice and source documents for full details.
View full official noticeWeekly recall digest
Get next week's recalls before you need them.
One email every Monday — official-source recalls for your country, and nothing else. Unsubscribe from any email.
The digest arrives once a week. For matching recall alerts after notices are processed, get the app.