Gas room air conditioner “イーナ” sold by 大阪ガス(株) - Inspection and repair
Official notice
20 Aug 2004
Last checked
28 Oct 2026
An official CAA Japan notice concerns Gas room air conditioner “イーナ” sold by 大阪ガス(株) - Inspection and repair. It has been found that incorrect assembly of internal components in some indoor units may, in very rare cases, cause smoke or fire. 大阪ガス株式会社 (President: Hirofumi Shibano) has found that, in certain models of the gas room air conditioner “イーナ” (manufactured by 東芝キヤリア株式会社) sold from April Heisei 13 to March Heisei 16, electrical tracking (*) may occur in very rare cases at the indoor unit's fan motor connector, potentially causing smoke or fire. The company will therefore inspect the indoor units and replace parts free of charge. Electrical tracking has been confirmed to result from the following combination of factors: • Due to manufacturing variations, some heat exchanger piping inside the indoor unit may contact the partition separating it from the fan motor. Under certain cooling or dehumidifying operating conditions, condensation may form on this partition, and the condensation water may reach the fan motor connector. • Electrolytic substances adhere to the fan motor connector. (*) Electrical tracking: When an electrically conductive substance (electrolyte) adheres to the surface of the insulation separating power supply terminals and moisture is added, spark discharges generate heat and carbonize the resin, potentially causing ignition. No incidents of smoke or fire have occurred in these gas room air conditioner models to date. To ensure continued safe use, the company will visit customers using these products in sequence based on its sales customer list to inspect the units and replace parts. Published 2004-08-20.
What to do now
Free inspection and repair.
Official notice
2004-08-20
The hazard
The hazard
It has been found that incorrect assembly of internal components in some indoor units may, in very rare cases, cause smoke or fire. 大阪ガス株式会社 (President: Hirofumi Shibano) has found that, in certain models of the gas room air conditioner “イーナ” (manufactured by 東芝キヤリア株式会社) sold from April Heisei 13 to March Heisei 16, electrical tracking (*) may occur in very rare cases at the indoor unit's fan motor connector, potentially causing smoke or fire. The company will therefore inspect the indoor units and replace parts free of charge. Electrical tracking has been confirmed to result from the following combination of factors: • Due to manufacturing variations, some heat exchanger piping inside the indoor unit may contact the partition separating it from the fan motor. Under certain cooling or dehumidifying operating conditions, condensation may form on this partition, and the condensation water may reach the fan motor connector. • Electrolytic substances adhere to the fan motor connector. (*) Electrical tracking: When an electrically conductive substance (electrolyte) adheres to the surface of the insulation separating power supply terminals and moisture is added, spark discharges generate heat and carbonize the resin, potentially causing ignition. No incidents of smoke or fire have occurred in these gas room air conditioner models to date. To ensure continued safe use, the company will visit customers using these products in sequence based on its sales customer list to inspect the units and replace parts.
How to check if you're affected
How to check if you're affected
Product identifiers are not currently available in RecallScope. Check the official notice before deciding whether your item is affected.
Checked manually this time?
Follow brands and keywords in the app to receive alerts for matching official notices.
Turn on recall alertsAffected products
Affected products
Product 1
Hazard
Where it was sold
Where it was sold
Retailer information is not currently available in RecallScope. Check the official notice for distribution details.
Location 1
Affected area 1
Company & contacts
Company & contacts
Brand
Manufacturer
Phone
Brand: 大阪ガス. Contact: 大阪ガス株式会社. Phone 0120-012-916.
Source & status
Source & status
Recall details
Recall details
Event id
Source tier
Documents, notices & source
See the official notice and source documents for full details.
View full official noticeWeekly recall digest
Get next week's recalls before you need them.
One email every Monday — official-source recalls for your country, and nothing else. Unsubscribe from any email.
The digest arrives once a week. For matching recall alerts after notices are processed, get the app.