Image available on the official notice.
JUKI "Hitachi-made clutch motor for professional sewing machines" (manufactured from 1967 to 1972) - Stop using
Official notice
1 Jan 2012
Last checked
28 Oct 2026
An official CAA Japan notice concerns JUKI "Hitachi-made clutch motor for professional sewing machines" (manufactured from 1967 to 1972) - Stop using. A fire incident occurred. Motor investigation report: This motor contains an internal capacitor for driving the motor. The following is an excerpt from the investigation report received from the motor manufacturer. "The capacitor is believed to have burned out because minute scratches or similar defects inside the capacitor gradually deteriorated over approximately 36 years of use, resulting in insulation breakdown. Internal heating caused the wax inside the capacitor to vaporize and escape through the seal. It is also presumed that the heating ultimately resulted in an open circuit. The motor coil burned out because the capacitor ceased functioning, preventing the motor from starting. Power continued to be supplied, causing the coil temperature to rise and ultimately resulting in heat generation and an open circuit. Based on the investigation results and the open-circuit condition of the coil and capacitor, the fire is believed to have extinguished itself. Our company (日立アプライアンス株式会社) has no record of the same phenomenon, and given approximately 40 years of operating experience, frequent occurrence is not expected. As described above, we consider this an extremely rare event caused by minute scratches or similar defects introduced during the capacitor's internal manufacturing process, together with deterioration over approximately 36 years of use. Furthermore, as described above, the capacitor and motor coil ultimately became open circuits and are enclosed in noncombustible covers made of iron or similar materials. We therefore consider that the damage will not spread further." Published 2012-01-01.
What to do now
Although the motor manufacturer has reported that it considers the fire incident "an extremely rare event based on the circumstances in which it occurred," considering when this product was manufactured, our company asks customers using the affected product to stop using it because deterioration of electrical components over time could cause an accident similar to this case. We cannot accept repairs because both the repair service period and the supply of repair parts for this product have ended. Thank you for your understanding.
Official notice
2012-01-01
The hazard
The hazard
A fire incident occurred. Motor investigation report: This motor contains an internal capacitor for driving the motor. The following is an excerpt from the investigation report received from the motor manufacturer. "The capacitor is believed to have burned out because minute scratches or similar defects inside the capacitor gradually deteriorated over approximately 36 years of use, resulting in insulation breakdown. Internal heating caused the wax inside the capacitor to vaporize and escape through the seal. It is also presumed that the heating ultimately resulted in an open circuit. The motor coil burned out because the capacitor ceased functioning, preventing the motor from starting. Power continued to be supplied, causing the coil temperature to rise and ultimately resulting in heat generation and an open circuit. Based on the investigation results and the open-circuit condition of the coil and capacitor, the fire is believed to have extinguished itself. Our company (日立アプライアンス株式会社) has no record of the same phenomenon, and given approximately 40 years of operating experience, frequent occurrence is not expected. As described above, we consider this an extremely rare event caused by minute scratches or similar defects introduced during the capacitor's internal manufacturing process, together with deterioration over approximately 36 years of use. Furthermore, as described above, the capacitor and motor coil ultimately became open circuits and are enclosed in noncombustible covers made of iron or similar materials. We therefore consider that the damage will not spread further."
How to check if you're affected
How to check if you're affected
Product identifiers are not currently available in RecallScope. Check the official notice before deciding whether your item is affected.
Checked manually this time?
Follow brands and keywords in the app to receive alerts for matching official notices.
Turn on recall alertsAffected products
Affected products
Product 1
Hazard
Where it was sold
Where it was sold
Retailer information is not currently available in RecallScope. Check the official notice for distribution details.
Location 1
Affected area 1
Company & contacts
Company & contacts
Brand: Juki. Contact: JUKI家庭製品お客様センター(株). Phone 0120-677-601.
Source & status
Source & status
Recall details
Recall details
Event id
Source tier
Documents, notices & source
See the official notice and source documents for full details.
View full official noticeWeekly recall digest
Get next week's recalls before you need them.
One email every Monday — official-source recalls for your country, and nothing else. Unsubscribe from any email.
The digest arrives once a week. For matching recall alerts after notices are processed, get the app.