Open official notice

Yamazen “Electric space heaters (carbon heaters)” (manufactured August~September 2003) - Repair

Official notice

21 Feb 2005

Last checked

28 Oct 2026

RecallScope risk estimate:HighCAA Japan

An official CAA Japan notice concerns Yamazen “Electric space heaters (carbon heaters)” (manufactured August~September 2003) - Repair. A fire occurred that burned the product. Recall details: It was found that a defect in components of the oscillating mechanism can, in very rare cases, cause an electrical wire to break, potentially resulting in smoke or ignition. Published 2005-02-21.

What to do now

Repair or replacement with an improved product.

Units affected

14,654

Official notice

2005-02-21

The hazard

A fire occurred that burned the product. Recall details: It was found that a defect in components of the oscillating mechanism can, in very rare cases, cause an electrical wire to break, potentially resulting in smoke or ignition.

How to check if you're affected

Compare the product name and identifiers below with the item you own. Check the official notice for the affected products and next steps.

Lots

25HD~31HD及び01JD~26JD

Models

カーボンヒーター CBH-D900 8, 540台 CBHI-D900 6, 114台 合計14, 654台

Checked manually this time?

Follow brands and keywords in the app to receive alerts for matching official notices.

Turn on recall alerts

Affected products

Product 1

電気ストーブ YAMAZEN カーボンヒーター

Units affected

14,654

Hazard

A fire occurred that burned the product. Recall details: It was found that a defect in components of the oscillating mechanism can, in very rare cases, cause an electrical wire to break, potentially resulting in smoke or ignition.

Where it was sold

Retailer information is not currently available in RecallScope. Check the official notice for distribution details.

Location 1

JP · Japan

Affected area 1

JP · Japan

Company & contacts

Brand

山善

Manufacturer

株式会社山善

Phone

0120-680-286

Brand: 山善. Contact: 株式会社山善. Phone 0120-680-286.

Source & status

Source

Tier

official

Category

ELECTRONICS

Official classification

消費者庁 — 修理

Recall details

Event id

CAA-00000007527

Units affected

14,654

Source tier

official

Documents, notices & source

See the official notice and source documents for full details.

View full official notice
Something wrong on this page?

Weekly recall digest

Get next week's recalls before you need them.

One email every Monday — official-source recalls for your country, and nothing else. Unsubscribe from any email.

The digest arrives once a week. For matching recall alerts after notices are processed, get the app.

This recall was published 21 Feb 2005. The next one won't wait for you to search.

RecallScope checks listed publishers for the brands and VINs you follow, and can alert you when a matching notice is processed.

apple-buttongoogle-button