Open official notice

GE Healthcare, Aespire 7900, 1009-9012-000 & Aespire View, 1009-9212-000. The family of GE Datex-Ohmeda Aespire anesthesia systems with

Official notice

27 Jan 2016

RecallScope risk estimate:MediumFDA

An official FDA notice concerns GE Healthcare, Aespire 7900, 1009-9012-000 & Aespire View, 1009-9212-000. The family of GE Datex-Ohmeda Aespire anesthesia systems with. The Drive Gas Check Valve of certain Anesthesia products could become stuck in a fixed open position, which could cause pressure to build in the mechanical ventilation cycle. If this issue is left unresolved, it could result in excessive or prolonged pressure in the patient breathing circuit during ventilation potentially resulting in barotrauma. Published 2016-01-27.

What to do now

This recall has been terminated. See the official FDA notice for the latest status.

Units affected

1,081

Recall number

Z-0677-2016

Official notice

2016-01-27

The hazard

The Drive Gas Check Valve of certain Anesthesia products could become stuck in a fixed open position, which could cause pressure to build in the mechanical ventilation cycle. If this issue is left unresolved, it could result in excessive or prolonged pressure in the patient breathing circuit during ventilation potentially resulting in barotrauma.

How to check if you’re affected

Compare the product name and identifiers below with the item you own. Check the official notice for the affected products and next steps.

Event Ids

72943

Recall Numbers

Z-0677-2016

Checked manually this time?

Follow brands and keywords in the app to receive alerts for matching official notices.

Turn on recall alerts

Affected products

Product 1

GE Healthcare, Aespire 7900, 1009-9012-000 & Aespire View, 1009-9212-000. The family of GE Datex-Ohmeda Aespire anesthesia systems with 7900 ventilator (Aespire 7900 and Aespire View) is intended to provide general inhalation anesthesia and ventilatory support to a wide range of patients. The devices are intended for volume or pressure control ventilation.

Units affected

1,081

Hazard

The Drive Gas Check Valve of certain Anesthesia products could become stuck in a fixed open position, which could cause pressure to build in the mechanical ventilation cycle. If this issue is left unresolved, it could result in excessive or prolonged pressure in the patient breathing circuit during ventilation potentially resulting in barotrauma.

Where it was sold

Retailer information is not currently available in RecallScope. Check the official notice for distribution details.

Location 1

US · United States

Affected area 1

US · United States

Affected area 2

AE · United Arab Emirates

Affected area 3

AR · Argentina

Affected area 4

AT · Austria

Affected area 5

AU · Australia

Affected area 6

BE · Belgium

Affected area 7

BR · Brazil

Affected area 8

CA · Canada

Affected area 9

CH · Switzerland

Affected area 10

CL · Chile

Affected area 11

CN · China

Affected area 12

CO · Colombia

Affected area 13

CR · Costa Rica

Affected area 14

CZ · Czech Republic

Affected area 15

DE · Germany

Affected area 16

DK · Denmark

Affected area 17

EE · Estonia

Affected area 18

EG · Egypt

Affected area 19

ES · Spain

Affected area 20

FI · Finland

Affected area 21

FR · France

Affected area 22

GB · United Kingdom

Affected area 23

GR · Greece

Affected area 24

GT · Guatemala

Affected area 25

HK · Hong Kong

Affected area 26

HU · Hungary

Affected area 27

IE · Ireland

Affected area 28

IL · Israel

Affected area 29

IN · India

Affected area 30

IS · Iceland

Affected area 31

IT · Italy

Affected area 32

JO · Jordan

Affected area 33

JP · Japan

Affected area 34

KR · South Korea

Affected area 35

KW · Kuwait

Affected area 36

LT · Lithuania

Affected area 37

LV · Latvia

Affected area 38

MX · Mexico

Affected area 39

MY · Malaysia

Affected area 40

NL · Netherlands

Affected area 41

NO · Norway

Affected area 42

NZ · New Zealand

Affected area 43

PE · Peru

Affected area 44

PK · Pakistan

Affected area 45

PL · Poland

Affected area 46

RO · Romania

Affected area 47

RS · Serbia

Affected area 48

SA · Saudi Arabia

Affected area 49

SE · Sweden

Affected area 50

SG · Singapore

Affected area 51

SK · Slovakia

Affected area 52

TH · Thailand

Affected area 53

TR · Turkey

Affected area 54

TW · Taiwan

Affected area 55

VE · Venezuela

Affected area 56

VN · Vietnam

Affected area 57

ZA · South Africa

Company & contacts

Manufacturer

GE Medical Systems, LLC

Phone

Not provided

Brand: GE Medical. Contact: GE Medical Systems, LLC.

Source & status

Source

Tier

official

Category

Tech & Electronics

Official classification

Class II

Recall details

Recall number

Z-0677-2016

Event ID

72943

Units affected

1,081

Status

terminated

Source tier

official

Documents, notices & source

See the official notice and source documents for full details.

View full official notice
Something wrong on this page?

Weekly recall digest

Get next week’s recalls before you need them.

One email every Monday with official-source recalls for your country, and nothing else. Unsubscribe from any email.

The digest arrives once a week. For matching recall alerts after notices are processed, get the app.

This recall was published 27 Jan 2016. The next one won’t wait for you to search.

RecallScope checks listed publishers for the brands and VINs you follow, and can alert you when a matching notice is processed.

apple-buttongoogle-button