Image not available in RecallScope.
Teleflex(R) Percuvance(TM) Percutaneous Surgical System, Components: (a) 5 mm Atraumatic Johans Grasper, Catalog Number PCVJG5 (b) 5 mm
Official notice
8 Nov 2017
Teleflex(R) Percuvance(TM) Percutaneous Surgical System, Components: (a) 5 mm Atraumatic Johans Grasper, Catalog Number PCVJG5 (b) 5 mm Maryland Dissector, Catalog Number PCVMD5 (c) 5 mm Hem-o-lok Clip Applier, Catalog Number PCVHCA5 (d) 5 mm Traumatic Gripper Grasper, Catalog Number PCVGG5 (e) 5 mm Scissors, Catalog Number PCVSC5 The Percuvance Percutaneous Surgical System is a family of instruments used to perform laparoscopic procedures. Without the need for additional insertion conduits (trocars), the 2.9mm insulated Shafts are inserted percutaneously with the assistance of an Introducer needle tool tip. The Shaft is then advanced retrograde through a 5mm, or larger, port to facilitate the extracorporeal attachment of interchangeable Tool Tips. These interchangeable tools can be used to grasp, retract, manipulate, cut, coagulate and deliver Hem-o-lok¿ ligating clips to soft tissue. Each Percuvance System Handle includes an integrated male cautery adapter that can be connected to most monopolar electrosurgical units (ESU) via a standard 4mm monopolar cable.
What to do now
This recall has been terminated. See the official FDA notice for the latest status.
Units affected
3,904
Recall number
Z-0059-2018
Official notice
2017-11-08
The hazard
The hazard
Teleflex is recalling these products because the jaws of the tool tip may break, causing a fragment of the tool tip to fall off during use.
How to check if you’re affected
How to check if you’re affected
Compare the product name and identifiers below with the item you own. Check the official notice for the affected products and next steps.
Lots
Event Ids
Recall Numbers
Checked manually this time?
Follow brands and keywords in the app to receive alerts for matching official notices.
Turn on recall alertsAffected products
Affected products
Product 1
Units affected
Hazard
Where it was sold
Where it was sold
Retailer information is not currently available in RecallScope. Check the official notice for distribution details.
Location 1
Affected area 1
Affected area 2
Affected area 3
Affected area 4
Affected area 5
Affected area 6
Affected area 7
Company & contacts
Company & contacts
Brand: Teleflex Medical. Contact: Teleflex Medical.
Source & status
Source & status
Recall details
Recall details
Recall number
Event ID
Units affected
Status
Source tier
Documents, notices & source
See the official notice and source documents for full details.
View full official noticeWeekly recall digest
Get next week’s recalls before you need them.
One email every Monday with official-source recalls for your country, and nothing else. Unsubscribe from any email.
The digest arrives once a week. For matching recall alerts after notices are processed, get the app.