Mcgrath™ mac video laryngoscope
Official notice
23 Jul 2024
Last checked
23 Jul 2024
An official Health Canada notice concerns Mcgrath™ mac video laryngoscope. Medtronic is issuing a voluntary recall for item codes 300-000-000 and 300-200-000 (section 1). This notice also includes information related to an addendum to the instructions for use (IFU) for item code 301-000-000 (section 2). Section 1 (for item codes 300-000-000 and 300-200-000) : Customers should immediately discontinue use of these devices that are being recalled. Customers should uninstall the battery assembly from these devices, dispose as per local procedure and follow manufacturer's instructions for returning the devices that are being recalled. To date, manufacturer has determined that the battery management system within the devices being recalled is not sufficient to mitigate against depletion of the battery voltage below the design threshold. Batteries that are depleted below the design threshold may increase the risk of the battery becoming unstable, which may lead to a thermal event followed by a risk of explosion. A thermal event followed by a risk of explosion of the battery assembly can potentially cause caregivers and/or patients to experience burns, lacerations, tinnitus, hearing impairment and acoustic shock. The potential for a delay to treatment, respiratory failure, hypoxia, unspecified tissue injury, scar tissue, foreign body in patient or caregiver, tooth loss, and eye injury also exist. There also exists the potential for damage to surrounding equipment or surfaces. This notice follows the receipt of two customer reports stating that the installed battery experienced a thermal event, which resulted in an explosion of the battery assembly before patient use. In one of these two instances, there were caregiver injuries. Section 2 (for item code 301-000-000) : Item code 301-000-000 are not being removed and are safe and effective for patient use. Next-generation laryngoscopes include an advanced battery management system that maintains the battery within intended voltage usage levels and renders them inoperable when the battery voltage falls below the device design threshold. Manufacturer is issuing an addendum to the instructions for use (IFU). This addendum will include the following warnings regarding proper battery handling. Improper battery handling can increase the risk of a thermal event. Battery assembly (340-000-000) is labelled with a "use by date". Do not use a battery past the "use by date". Refer to the product instructions for use (IFU) for proper battery storage conditions. Any battery assemblies that have not been stored in these conditions should be disposed of per local guidelines. Do not use a battery assembly, installed or uninstalled, that has been dropped as it may have sustained internal damage that is not visible. Dispose of any dropped battery assembly in accordance with facility's procedure and replace with a new labeled battery assembly. Recall start date: July 18, 2024 Published 2024-07-23.
What to do now
Contact the manufacturer if you require additional information.
Recall number
75854
Official notice
2024-07-23
The hazard
The hazard
Medtronic is issuing a voluntary recall for item codes 300-000-000 and 300-200-000 (section 1). This notice also includes information related to an addendum to the instructions for use (IFU) for item code 301-000-000 (section 2). Section 1 (for item codes 300-000-000 and 300-200-000) : Customers should immediately discontinue use of these devices that are being recalled. Customers should uninstall the battery assembly from these devices, dispose as per local procedure and follow manufacturer's instructions for returning the devices that are being recalled. To date, manufacturer has determined that the battery management system within the devices being recalled is not sufficient to mitigate against depletion of the battery voltage below the design threshold. Batteries that are depleted below the design threshold may increase the risk of the battery becoming unstable, which may lead to a thermal event followed by a risk of explosion. A thermal event followed by a risk of explosion of the battery assembly can potentially cause caregivers and/or patients to experience burns, lacerations, tinnitus, hearing impairment and acoustic shock. The potential for a delay to treatment, respiratory failure, hypoxia, unspecified tissue injury, scar tissue, foreign body in patient or caregiver, tooth loss, and eye injury also exist. There also exists the potential for damage to surrounding equipment or surfaces. This notice follows the receipt of two customer reports stating that the installed battery experienced a thermal event, which resulted in an explosion of the battery assembly before patient use. In one of these two instances, there were caregiver injuries. Section 2 (for item code 301-000-000) : Item code 301-000-000 are not being removed and are safe and effective for patient use. Next-generation laryngoscopes include an advanced battery management system that maintains the battery within intended voltage usage levels and renders them inoperable when the battery voltage falls below the device design threshold. Manufacturer is issuing an addendum to the instructions for use (IFU). This addendum will include the following warnings regarding proper battery handling. Improper battery handling can increase the risk of a thermal event. Battery assembly (340-000-000) is labelled with a "use by date". Do not use a battery past the "use by date". Refer to the product instructions for use (IFU) for proper battery storage conditions. Any battery assemblies that have not been stored in these conditions should be disposed of per local guidelines. Do not use a battery assembly, installed or uninstalled, that has been dropped as it may have sustained internal damage that is not visible. Dispose of any dropped battery assembly in accordance with facility's procedure and replace with a new labeled battery assembly. Recall start date: July 18, 2024
How to check if you're affected
How to check if you're affected
Compare the VIN on your vehicle against the official list. If your VIN is listed, follow the official notice.
Recall Numbers
Checked manually this time?
The app watches your VIN and alerts you automatically next time — no searching, no checking back.
Turn on automatic VIN checksAffected products
Affected products
Product 1
Product 2
Risk / hazard
Where it was sold
Where it was sold
The source does not list specific retailers. See the official notice for where affected vehicles were sold.
Location 1
Affected area 1
Company & contacts
Company & contacts
Brand
Manufacturer
Phone
Brand: Covidien, Mcgrath™ Mac Video Laryngoscope.
Source & status
Source & status
Source
Tier
Category
Classification
App estimate
Recall details
Recall details
Recall number
Classification
Source tier
Documents, notices & source
See the official notice and source documents for full details.
View full official noticeRelated recalls

Endoflip system

Polysorb coated braided absorbable single stitch reload for use with the endo stitch and sils stitch suturing devices

Bipolar hugo ras systems

Hugo ras tower, 120v

Esoflip dilation catheter 30mm

Hugo ras tower, 120v

Hugo ras surgeon console

Auto suture blunt tip and structural balloon trocar

Sofsilk™ braided silk sutures and ti-cron™ coated braided polyester sutures

Valleylab ft10 ft series energy platform

Hugo™ robotic-assisted surgery (ras) tower, 120v

Mahurkar acute high pressure triple lumen catheter kit curved extensions
Weekly recall digest
Get next week's recalls before you need them.
One email every Monday — official-source recalls for your country, and nothing else. Unsubscribe from any email.
The digest is the slow lane — one email a week. For instant, severity-gated alerts the moment a notice is published, get the app.
This recall was published 23 Jul 2024. The next one won't wait for you to search.
RecallScope watches official sources for the brands and VINs you follow, and alerts you the moment a new notice is published.