No image published for this recall

No image published for this recall

P47 Stereo Head Mounted Bluetooth Headphones

Official notice

7 Jul 2023

Last checked

7 Jul 2023

Critical riskEU Safety Gate

An official EU Safety Gate notice concerns P47 Stereo Head Mounted Bluetooth Headphones. The white plastic in the cable, the solder in connection to battery and the solders on the PCB of the product have excessive concentrations of lead (measured values up to 0.26%, 31.8% and 75.9% by weight, respectively).Lead poses a risk to the environment.The white plastic material in the cable has excessive an concentration of bis(2-ethylhexyl) phthalate (DEHP), dibutyl phthalate (DBP) and short chain chlorinated paraffins (SCCPs) (measured values up to 1.69%, 1.67 % and 6.49 % by weight, respectively).The black leather material of the product has an excessive concentration of bis(2-ethylhexyl) phthalate (DEHP) (measured value up to 19.3%).These phthalates may harm the health by causing possible damage to the reproductive system.SCCPs persist in the environment, are toxic to aquatic organisms at low concentrations and bio-accumulate in wildlife and humans, posing a risk to human health and the environment. Prolonged exposure to them through the skin may cause cancer The product does not comply with the requirements of the Commission Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive) nor with the Persistent Organic Pollutants (POP) Regulation. Published 2023-07-07.

What to do now

The source does not provide specific consumer instructions. Follow the official EU Safety Gate notice for next steps.

Recall number

INFO/00093/23

Official notice

2023-07-07

The hazard

The white plastic in the cable, the solder in connection to battery and the solders on the PCB of the product have excessive concentrations of lead (measured values up to 0.26%, 31.8% and 75.9% by weight, respectively).Lead poses a risk to the environment.The white plastic material in the cable has excessive an concentration of bis(2-ethylhexyl) phthalate (DEHP), dibutyl phthalate (DBP) and short chain chlorinated paraffins (SCCPs) (measured values up to 1.69%, 1.67 % and 6.49 % by weight, respectively).The black leather material of the product has an excessive concentration of bis(2-ethylhexyl) phthalate (DEHP) (measured value up to 19.3%).These phthalates may harm the health by causing possible damage to the reproductive system.SCCPs persist in the environment, are toxic to aquatic organisms at low concentrations and bio-accumulate in wildlife and humans, posing a risk to human health and the environment. Prolonged exposure to them through the skin may cause cancer The product does not comply with the requirements of the Commission Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive) nor with the Persistent Organic Pollutants (POP) Regulation.

Checked manually this time?

The app alerts you when a new official recall is published — no searching, no checking back.

Turn on recall alerts

Affected products

Product 1

Headphones

Product 2

P47 Stereo Head Mounted Bluetooth Headphones

Risk / hazard

The white plastic in the cable, the solder in connection to battery and the solders on the PCB of the product have excessive concentrations of lead (measured values up to 0.26%, 31.8% and 75.9% by weight, respectively).Lead poses a risk to the environment.The white plastic material in the cable has excessive an concentration of bis(2-ethylhexyl) phthalate (DEHP), dibutyl phthalate (DBP) and short chain chlorinated paraffins (SCCPs) (measured values up to 1.69%, 1.67 % and 6.49 % by weight, respectively).The black leather material of the product has an excessive concentration of bis(2-ethylhexyl) phthalate (DEHP) (measured value up to 19.3%).These phthalates may harm the health by causing possible damage to the reproductive system.SCCPs persist in the environment, are toxic to aquatic organisms at low concentrations and bio-accumulate in wildlife and humans, posing a risk to human health and the environment. Prolonged exposure to them through the skin may cause cancer The product does not comply with the requirements of the Commission Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive) nor with the Persistent Organic Pollutants (POP) Regulation.

Where it was sold

The source does not list specific retailers. See the official notice for where affected products were sold.

Location 1

DE · Germany

Location 2

FR · France

Affected area 1

DE · Germany

Affected area 2

FR · France

Source & status

Tier

beta

Category

ELECTRONICS

Classification

Other types of alerts — Chemical, Environment

App estimate

critical

Recall details

Recall number

INFO/00093/23

Classification

Other types of alerts — Chemical, Environment

Source tier

beta

Documents, notices & source

See the official notice and source documents for full details.

View full official notice
Something wrong on this page?

Weekly recall digest

Get next week's recalls before you need them.

One email every Monday — official-source recalls for your country, and nothing else. Unsubscribe from any email.

The digest is the slow lane — one email a week. For instant, severity-gated alerts the moment a notice is published, get the app.

This recall was published 7 Jul 2023. The next one won't wait for you to search.

RecallScope watches official sources for the brands and VINs you follow, and alerts you the moment a new notice is published.