An official Health Canada notice concerns Olympus distal attachment and disposable emr kit. Devices contain di-2-ethylhexyl phthalate (DEHP). Olympus has previously announced on the labeling that the product contains DEHP. Since Olympus has confirmed that alternative products can be provided, Olympus has decided to ask customers to cease using the subject products and to further remove them. In general, potential patient harms associated with the use of plastic products containing DEHP include: chemical exposure, hypersensitivity/allergic reaction, endocrine disruption, reproductive and developmental toxicity and carcinogenicity. Long term DEHP toxicity may occur if a distal attachment inadvertently becomes a retained foreign body with resultant leaching over time. Olympus has not received any reports of these harms occurring from the use of our products. Recall start date: August 17, 2023 Published 2023-08-31.
What to do now
Contact the manufacturer if you require additional information.
Recall number
74217
Official notice
2023-08-31
The hazard
The hazard
Devices contain di-2-ethylhexyl phthalate (DEHP). Olympus has previously announced on the labeling that the product contains DEHP. Since Olympus has confirmed that alternative products can be provided, Olympus has decided to ask customers to cease using the subject products and to further remove them. In general, potential patient harms associated with the use of plastic products containing DEHP include: chemical exposure, hypersensitivity/allergic reaction, endocrine disruption, reproductive and developmental toxicity and carcinogenicity. Long term DEHP toxicity may occur if a distal attachment inadvertently becomes a retained foreign body with resultant leaching over time. Olympus has not received any reports of these harms occurring from the use of our products. Recall start date: August 17, 2023
How to check if you're affected
How to check if you're affected
Compare the product name and identifiers below with the item you own. Follow the official notice if they match.
Recall Numbers
Checked manually this time?
The app alerts you when a new official recall is published — no searching, no checking back.
Turn on recall alertsAffected products
Affected products
Product 1
Risk / hazard
Where it was sold
Where it was sold
The source does not list specific retailers. See the official notice for where affected products were sold.
Location 1
Affected area 1
Company & contacts
Company & contacts
Manufacturer
Phone
Brand: Olympus Medical, Olympus Distal Attachment And Disposable Emr Kit.
Source & status
Source & status
Source
Tier
Category
Classification
App estimate
Recall details
Recall details
Recall number
Classification
Source tier
Documents, notices & source
See the official notice and source documents for full details.
View full official noticeWeekly recall digest
Get next week's recalls before you need them.
One email every Monday — official-source recalls for your country, and nothing else. Unsubscribe from any email.
The digest is the slow lane — one email a week. For instant, severity-gated alerts the moment a notice is published, get the app.
This recall was published 31 Aug 2023. The next one won't wait for you to search.
RecallScope watches official sources for the brands and VINs you follow, and alerts you the moment a new notice is published.